Example of DynamicCondenser with Fluid not working
The example ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicCondenser
is not working with Dymola23x or Dymola21x (both with master or develop branch).
Failure to solve real system of equations.
Unknowns:
DynamicCondenser.DynamicCondenser.Qcond
DynamicCondenser.DynamicCondenser.QcondS
Equations:
0.0 = DynamicCondenser.DynamicCondenser.Qcond-DynamicCondenser.DynamicCondenser.Cl.Q +DynamicCondenser.DynamicCondenser.QcondS;
0.0 = DynamicCondenser.DynamicCondenser.CvBP.Q+DynamicCondenser.DynamicCondenser.CvGCT.Q -DynamicCondenser.DynamicCondenser.Qcond-DynamicCondenser.DynamicCondenser.QcondS;